In this post, we will show you how to replace the heater relay board in your 2001 to 2009 Hot Spring, Tiger River, or Limelight spa. For your safety, make sure you follow the directions in the post carefully.

Watch the video tutorial of How to Replace the IQ2020 Heater Relay Board below.

Tools You Will Need

  • Small Flathead Screwdriver
  • Standard Phillips Screwdriver
  • Wire Stripping Tool

Safety First!

Make sure you turn the power to the spa off before doing any of these steps.

Removing the Heater Relay Board.

Step 1

First, remove the lid from the IQ 2020 control box using a Phillips screwdriver. Double-check that the power is turned off, then disconnect the black and white leads of the heater from the heater relay board.

Step 2

Next, you need to remove the center support bracket from the box by loosening the screw on the right side of the bracket.

Step 3

Remove the two green grounding wires secured to the board.

Step 4

Disconnect the main power wires from the terminal block. To release the wires push a small flat-head screwdriver up into the square slot above the wire and then pull the handle of the screwdriver up and pull the wire out. After the main power wires are all disconnected, disconnect the three jumper wires coming from the main motherboard over to the heater relay board.

Step 5

Now, remove the two screws holding the metal L bracket to the heater relay board and remove the bracket.

Step 6

Remove the heater relay board by grabbing it on either side of the plastic clip in the upper right-hand corner. Work it back and forth to free it from the pins the clip is connected to.

NOTE: Sometimes when a heater relay board goes bad, you’ll see burn marks on the backside of it where the relays burnt out.

Replace the Heater Relay Board.

Step 1

Place the new board into the control box and push down on the white plastic clip firmly to make sure the pins connect securely to the new board. Reinstall the metal L bracket to hold the board in place. The L bracket is held in place by the two Phillips head screws you removed earlier.

Step 2

Reinstall the heater ground wire, spa ground wire and reconnect the three wires coming from the mainboard over to the heater relay board. The color of each wire is marked on the heater relay board next to their corresponding connector.

Reinstall Heater & Power Wires

Step 1

After double-checking that the power is still turned off, twist the ends of each power wire to make sure they don’t fray when you reinsert them. To reinsert each wire, push a small flathead screwdriver into the square slot above the wire entrance and pry upward. While you are prying carefully insert the wire.

NOTE:

The wire should go in easily if you have the connector properly open. The connectors are labeled 1, H1, 2, 3, 4, and 5. Make sure you put the wires in the same numbered spots as before. Don’t be thrown off by the extra connector labeled H1 (that is where one of the heater wires will be connected). Next, we will connect the heater wires to the two connectors labeled H1 and H2.

Install the Heater Wires

Step 1

Because of the different type of connections on the new board, you may need to clip the old connectors from the heater wires and strip off about a 1/2 inch of the plastic insulator from the wire. You can use any type of wire stripper to do this.

Step 2

Twist the ends of the exposed wires so they don’t fray then insert one wire into h1 and the other in h2. It doesn’t matter which color wire goes to h1 and which goes to h2.

Step 3

Next, we need to install the power jumpers. The power jumpers slide into grooves at the top of the terminal block. You can use a small flathead screwdriver to push the power jumper(s) down all the way.

Note:

  • If your spa is wired for 120V, you will need to use 2 power jumpers. (Connect terminals 1,2 & 3,4,5)
  • If your spa is wired for 240V, you won’t need any jumpers.
  • If your spa was 120V but got converted to 240V you will need to use 1 jumper. (Connect terminals 3,4 & 5)

The h1 terminal will be jumped as well if you don’t remove the center prong from the power jumper. Remove the middle of the 3 prongs from the power jumper and then install the jumper. Make sure you push the jumpers in securely using a flathead screwdriver.

Step 4

Now, reinstall the center support bracket using the Phillips head screw you removed before.

Step 5

Turn the power back on and check to make sure the “HTR ON” light is lit on the motherboard. If it is, check the voltage between terminals H1 and H2 to make sure that you are getting the proper voltage to the heater.

Now all that’s left to do now is put the control box lid back in place. Make sure you use the new screws that came with the new heater relay board because the old screws are too long for the new board.

Thanks for reading! We hope you enjoyed this post on how to replace the Heater Relay Board in your HotSpring Spa.


Our goal here at Backyard Plus is to help save you money by avoiding costly service calls for repairs that you can easily do yourself!

If you are looking for HotSpring Spa replacement parts or water care products for your spa, we have what you need! backyardplus.com

For more helpful tips and How-To Videos, visit our YouTube channel!

Thanks for reading!

If there are any topics you would like to learn about pertaining to your HotSpring Spa, please let us know.

Like and follow us on FaceBook!