Circ Pump, Watkins Silentflo 5002, (2-Speed)

Item #: 75073

Description-

OBSOLETE-DISCONTINUED BY THE FACTORY-Use the 74427

This two speed circulation pump was used on 1995-1996 Hot Spring Grandee, Highlife, 220v Sovereign (IH model), 220v. Classic (FH model), Landmark & Summit. Also used on the Tiger River Khyber, 220v. Manora (MH model) and the 220v Tondi (PH model). The second speed feature insured that the water flowing through the original 5500 Cartridge Style Heater would flow fast enough to prevent it from tripping the high limit sensor. Even though the above mentioned spa models were wired 220 volts this circulation pump is a 115 volts just like the spa light.

Not sure where to find your serial number? Click here.

Spa brands and their serial # ranges that require this circulation pump:
Hot Spring Models
Model Serial Range Year
Classic FH-151001 to FH-469999 1995-1996
Grandee G-151001 to G-469999 1995-1996
Sovereign IH-151001 to IH-469999 1995-1996
Highlife K-151001 to K-469999 1995-1996
Summitt R-151001 to R-469999 1995-1996
Landmark S-151001 to S-469999 1995-1996
 
Tiger River Models
Model Serial Range Year
Khyber L-151001 to L-469999 1995-1996
Manora MH-351001 to MH-469999 1995-1996
Tondi PH-351001 to PH-469999 1995-1996
 


Note:
These circulation pumps are water lubricated and cooled and require the presence of water at all times. These pumps should NOT be operated without water present in the spa. If a "dry run" occurs , the pump has an internal safety device (thermal cut-off) that will automatically shut it down should it overheat. To reset this pump simply power down the spa for 10 seconds then power it back up.

Technical Specs: Minimum flow for the circulation pump is 1 gallon in 30 seconds for low speed and 1 gallon in 20 seconds on high speed.

Removal of old pump

  1. Disconnect power to the spa.
  2. Access the equipment compartment.
  3. Unplug the circulation pump from the control box.
  4. If the spa is filled with water, clamp the circulation pump inlet and outlet tubing with Hose Clamp Pliers or insert wine bottle corks into the ends of the tubing.
  5. Remove the bonding wire and base bracket screws.
  6. Use pliers to slide the spring clamps located on the inlet and outlet fittings back onto the vinyl tubing.
  7. Remove the vinyl tubing from the pump inlet and outlet fittings.
  8. Disconnect the electrical cord for the old pump. Take note of the electrical hookup.

Installation of the new pump

  1. Install the original electrical cord onto the new pump.
  2. Reverse steps 3 to 7 of the Circulation Pump Removal instructions.
  3. Check for water leaks.
  4. Reconnect power to the spa.
  5. Perform a water flow test.
  6. Check for any air in the plumbing lines. If air does not clear, bleed off the air at the closest tubing clamp.
  7. Reinstall the equipment compartment door.

Check Serial Number Compatibility

Price: Not available
Not Available

Related Items

Power Cord, Silentflo 5002, Tiger River '95-'96

This Silentflo 5002 power cord is for the 1995-1996 230 volt Tiger River Khyber, Manora (MH model) & Tondi (PH model) models only. Although the above mentioned spa models are connected to 230volts, the Silentflo 5002 is a 120volt pump and has been replaced with the new E5 circulation pump .

Price: $17.68
Spring Clamp, 3/4" (.97-1-.18)

3/4" spring clamp (aka wire clamp) is used to secure the 3/4 inch vinyl tubing (70315) to various components.

Note: Wear eye protection when squeezing these little rascals. Service techs typically use either needle nose pliers or hose clamp pliers to squeeze then slide this spring clamp onto the vinyl tubing.

Price: $0.82